| Removal and Installation |
| 1. |
Remove the reservoir tank.
|
| 2. |
Install in the reverse order of removal. |
Repair procedures Refilling And Bleeding Never remove the reservoir tank cap when the engine is hot.
Components and components location Components 1. Cooling fan 2. Cooling fan motor 3. Cooling fan shroud Specifications Specifications Item Specification Fan type PULLER Fan speed control Resisor Air flow rate (㎥/h) 1,950 - 8% min.
Specifications Specifications Item Specifications Rated voltage DC 12 V Operating voltage DC 9 - 16 V Operating temperature range -22 to 167°F (-30 to 75°C) Dark current Max.
Schematic diagrams Connector and Terminal Function Repair procedures Removal When prying with a flat-tip screwdriver or use a prying trim tool, wrap it with protective tape, and apply protective tape around the related parts, to prevent dam